Instruction manual
4. Remove coil assembly.
5. Remove metal horizontal drain pan from coil assembly.
6. Remove horizontal drain pan support bracket from coil support rail and reinstall to the opposite side of the coil support rail.
7. Remove condensate drain plugs from 1 side of horizontal drain pan and install in drain connection openings on opposite side.
8. Convert air-seal assembly for horizontal right.
a. Remove air-seal assembly from coil by removing 4 screws.
b. Remove air splitter (B) from coil seal assembly by removing 3 screws. (See Fig. 5—factory-shipped inset.)
Fig. 4—Conversion for Horizontal Right Applications Using a Slope Coil
A90174
COIL MOUNTING
SCREW
BLOWER
ASSEMBLY
COIL SUPPORT
RAIL
COIL SUPPORT
RAIL
PRIMARY
CONDENSATE
DRAIN
REFRIGERANT
CONNECTIONS
SECONDARY
CONDENSATE
DRAIN
Fig. 5—Conversion for Horizontal Right Applications Using A-Coil
A91119
COIL
SUPPORT
RAIL
COIL
BRACKET
DRAIN PAN
SUPPORT
BRACKET
COIL
SUPPORT
RAIL
COIL
BRACKET
METAL HORIZONTAL
DRAIN PAN
SECONDARY
CONDENSATE
DRAIN
PRIMARY
CONDENSATE
DRAIN
REFRIGERANT
CONNECTIONS
AIR SEAL
ASSEMBLY
A
B
C
A
B
C
FACTORY
SHIPPED
HORIZONTAL
RIGHT
APPLICATION
—4—