User manual
I/O Shield
The Itox G7V300 motherboard uses the I/O shield supplied with the
motherboard. Refer to the main assembly guide for instructions on
installing the I/O shield.
Installing the Motherboard
STANDOFF INSTALLATION
1. Install the standoff, included in the chassis integration kit, in
location X as shown in the figure below.
HEATSINK INSTALLATION
1. Install the CPU following the instructions provided with the CPU.
2. Insert the heat sink support bracket into the motherboard from
the underside of the motherboard. The standoffs on the bracket
are inserted into the holes in the motherboard. Refer to Figure 1
NOTE
Make sure the top surface of the heat sink support bracket has the
mylar insulator. Failure to have the insulator in place will result in
the board not working.
FIGURE 1
3. Turn the motherboard over while holding the support bracket in
place. Place the new heat sink on the motherboard with the fan
to the front. Attach the heatsink using the 4 built-in screws. See
Figure 2
FIGURE 2
4. Connect the heatsink fan power cable to the motherboard. Refer
to Figure 2
INSTALLATION OF FRONT PANEL CONNECTORS
Connect Fan and Peripheral Cables
Connect the fan power Y-cable (PN: 10422-00) to the motherboard
fan connector. Connect the fans to the Y-cable. Connect the
peripherals. Refer to the Model 526 Assembly Guide for the
suggested peripheral cable routing.
ITOX
G7V300 ASSEMBLY INSTRUCTIONS
Copyright © 2005, Systium Technologies, LLC
PN: 91186-00
SySTIUM
TM
TECHNOLOGIES MOTHERBOARD READY
SM
SYSTEM • MODEL 526