User`s manual
TS Series Time Stamp User’s Manual
Page 12
CHANGING THE FUSE
Each model of the TS Series comes equipped with a fuse. The fuse protects the unit from
damage in case of a power surge or electrical overload. If too much power reaches the fuse,
the fuse burns out, or is "blown," stopping operation of the unit and avoiding costly damage.
To change the fuse:
1. Disconnect the power source.
2. Remove top cover and frame locking pin as described on Page 6. Lift top frame.
3. Locate the Fuse Holder Cap (Figure 9, Number 1).
4. Remove the fuse cap by turning counterclockwise. Remove the old fuse.
5. Insert a 3 Amp replacement fuse (Type 3AG or equivalent). Press down on fuse holder cap
and turn clockwise until it locks in place.
6. Close the top frame, install the frame locking pin, and install the top cover.
7. Connect the power source.
8. Make a sample registration. Reset the type wheels (Setting the Type Wheels, Page 6) and
digital display (Setting the Digital Display, Page 7).
Figure 9