CONSECUTIVE/DUPLICATE COUNT (Numbering Units)
Units equipped with the numbering feature may be configured for Consecutive Count,
advancing the number type wheel after each registration, Duplicate Count, advancing the
number type wheel after every two registrations., Triplicate Count, advancing the number type
wheel after every three registrations, or Quad Count, advancing the number type wheel after
every four registrations. All units are shipped with the Consecutive Count mode enabled. Units
having circuit board version “E” and above also support Triplicate and Quad numbering
options. (See figure 6b).
To switch to Duplicate Count mode, disconnect the power. Locate and remove the Access
Cover (Figure 4) using a Phillips-head screwdriver. The version of the Control Circuit installed
is indicated on the product label, on the underside of the unit, as well as on the circuit board,
itself. On version “D” circuit boards, the shunt is placed over 2 pins (Figure 6a). Remove the
shunt and place it over just 1 pin. To return to the Consecutive mode, reverse the procedure.
For units having circuit board version “E” and above, the DUP, TRIP, and QUAD numbering
features are selected by positioning the shunt according to (Figure 6b).