TS Time Stamp USER’S MANUAL
TS Series Time Stamp User’s Manual This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
TS Series Time Stamp User’s Manual SPECIFICATIONS PHYSICAL Height: Width: Depth: Weight: Case: Color: Power Cord Length: COMPONENTS Print Wheels: Printing Platen Assembly: Ribbon: Fuse: Digital Display: Timing Motor: Ribbon Drive Motor: Transformer: Numbering Solenoid: Print Solenoid: FEATURES Print Impact Adjustment: Time Format: POWER REQUIREMENTS Voltage: Current: Frequency: 7 inches 5 1/4 inches 11 inches 12 3/4 pounds (standard models) 14 pounds (numbering models) Impact Resistant Reinforced Lexan Co
TS Series Time Stamp User’s Manual INTRODUCTION The Simplex TS Series time stamps are considered "standard" by thousands of businesses and institutions because of their low initial cost and years of proven, trouble-free operation. The TS Series offers a wide variety of registration combinations that may be used for timing, numbering, and dating functions.
TS Series Time Stamp User’s Manual CONSECUTIVE/DUPLICATE COUNT Models TS30 and TS80 can repeat the same number once, twice, three times or four times before automatically advancing. (For jumper/shunt selection, see page 9, "Consecutive / Duplicate Count.") OPTIONAL FEATURES REPEAT/ADVANCE SWITCH Overrides automatic numbering advance to allow repeating the same number if desired, or advances to a higher number. (See page 8 for operating instructions.
TS Series Time Stamp User’s Manual GETTING STARTED Getting started with the TS Series is easy. There are only a couple of fundamental decisions that must be made. 1. Plug the unit into the wall outlet 2. Place the clock on top of the anti-skid rubber pad (included) 3. Set the type section 4. Set the digital clock (optional feature) INSTALLATION The TS Series time stamp installs easily on any tabletop or flat surface.
TS Series Time Stamp User’s Manual SETTING THE TYPE WHEELS As noted in the earlier sections TS SERIES MODELS and OPTIONAL FEATURES, the TS Series Models are available with a variety of date, time, and number wheels. You may set the applicable type wheels according to the following directions. 1. Disconnect the power source. 2. Remove the top cover by inserting the key in the back of the unit, turning the key clockwise, and pulling the cover up and forward. 3.
TS Series Time Stamp User’s Manual SETTING THE DIGITAL DISPLAY Models with a "C" affixed to their designation (TS50C and TS80C) denote units featuring a digital display. This display is factory-set for use in the 12-hour AM/PM format or the 24-hour (Continental) format. The digital display should always be synchronized with the time type wheels. To set the digital display and synchronize the display with the time type wheels, do the following: 1. Connect the power source. 2.
TS Series Time Stamp User’s Manual ADJUSTING PRINT IMPACT Print impact may be set to any desired level, from very hard to very light. The impact adjuster is located on the bottom of the unit. Using a small flat head screwdriver, turn the adjuster to the right to increase or left to decrease the impact. (Figure 4) Note: To extend the effective life-span of the unit, use the lightest adjustment possible, which still gives a legible imprint.
TS Series Time Stamp User’s Manual CONSECUTIVE/DUPLICATE COUNT (Numbering Units) Units equipped with the numbering feature may be configured for Consecutive Count, advancing the number type wheel after each registration, Duplicate Count, advancing the number type wheel after every two registrations., Triplicate Count, advancing the number type wheel after every three registrations, or Quad Count, advancing the number type wheel after every four registrations.
TS Series Time Stamp User’s Manual ADJUSTING THE REGISTRATION POSITION Depending on the type of document being stamped, it may be necessary to change the registration position. This can be accomplished by moving the trigger assembly. The trigger assembly has a range of motion of about two (2) inches forward or backward. The trigger assembly tells the unit how far the document must be inserted before activating the stamp.
TS Series Time Stamp User’s Manual CHANGING THE RIBBON TS Series time stamps use a silk ribbon for long-lasting, high-quality imprints. To avoid damaging the unit, use only 1307-5008 (purple), 1307-5009 (red) or 1307-5010 (black) ribbon. To change the ribbon: 1. Disconnect the power source. 2. Remove the top cover. Remove the frame locking pin and lift the top frame (as described on Page 6, Figure 2). 3. Pull the front spool plunger knob (Figure 8, Number 1) away from unit.
TS Series Time Stamp User’s Manual CHANGING THE FUSE Each model of the TS Series comes equipped with a fuse. The fuse protects the unit from damage in case of a power surge or electrical overload. If too much power reaches the fuse, the fuse burns out, or is "blown," stopping operation of the unit and avoiding costly damage. To change the fuse: 1. Disconnect the power source. 2. Remove top cover and frame locking pin as described on Page 6. Lift top frame. 3.
TS Series Time Stamp User’s Manual CHANGING THE PLATEN 1. Disconnect the power source. 2. Remove the top cover. Remove the frame locking pin and lift the top frame. Remove the ribbon (see Changing the Ribbon, Page 11). 3. Lift the printing platen assembly up and out of the frame. (Figure 10) 4. Insert the alternate printing platen assembly, using the guide pin for alignment. 5. Replace the ribbon. Close the top frame and install the frame locking pin. Install the top cover. 6.
TS Series Time Stamp User’s Manual Limited Warranty Subject to the limitations set forth below, SimplexGrinnell warrants that the Products shall be free from defects in material and workmanship under normal use for the period of 90 days commencing on the date of 1) first beneficial use of all or any part of Product if installed by SimplexGrinnell or 2) Product shipment, whichever is earlier.
Corporate Sales and Marketing: 50 Technology Drive, Westminster, MA 01441-0001, Toll Free: 1-888-7777-9237 Canada: 2400 Skymark Avenue, Mississauga, Ontario L4W 5K5 Telephone 1-800-565-5400 © 2011 SimplexGrinnell LP. All rights reserved. Printed in the U.S.A.