44-01-01: System Options for ARS
Select whether the ARS feature should use the time schedule (0=not
used, 1=used).
44-02-01: Dial Analysis Table for ARS Access – Dial
Set the Dial digits for the Pre-Transaction Table for selecting ARS(8 dig-
its).
44-02-02: Dial Analysis Table for ARS Access - Service Type
Set the Service Type (0-3) for the Pre-Transaction Table for selecting
ARS .
44-02-03: Dial Analysis Table for ARS Access - Additional Data
If a Service Type is selected in Program 44-02-02, set the additional
data, if required, for the Pre-Transaction Table for selecting ARS
44-02-04: Dial Analysis Table for ARS Access - Dial Tone Simulation
Determine if the Dial Tone Simulation is on (1) or off (0) for the Pre-
Transaction Table for selecting ARS .
44-03-01: Dial Analysis Extension Table – Dial
Set the Dial digits to be used for the Dial Extension Analyze Table.
44-03-02: Dial Analysis Extension Table - Table Number
Select the ARS/R-Route table number (0-500) to be used for the Dial
Extension Analyse Table.
44-03-03: Dial Analysis Extension Table - Table Number (251)
Select the ARS/R-Route table number (0-500) to be used for the Dial
Extension Analyse Table 251.
44-03-04: Dial Analysis Extension Table - Next Table Number
Select the Next Table Area Number (0-4) to be used for the Dial Exten-
sion Analyse Table 252.
44-04-01: ARS Selection for Time Schedule
Assign each ARS Selection number (1-500) to an ARS table number for
each ARS time mode. There are 8 time modes for ARS Access.
44-05-02: ARS Table - Delete Digits
For each ARS table (1-500) assign a priority number (1-4). Enter the
number of digits to be deleted (0-255).
44-05-03: ARS Table - Additional Dial Number
For each ARS table (1-500) assign a priority number (1-4). Enter the
number of additional digits to be Dialled (0-1000).
44-05-04: ARS Table - Beep Tone
For each ARS table (1-500) assign a priority number (1-4). Select
whether or not a beep is heard if a lower priority trunk group is used
(0=no beep, 1=beep).
44-05-05: ARS Table - Gain Table Number for Internal Call
For each ARS table (1-500) assign a priority number (1-4). Select the
gain table number to be used for internal calls (0-500).