Specifications

BC Biomedical Defibrillator Analyzer Series
DA-2006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $2150
A defibrillator analyzer developed for testing all external defib-
rillators. The unit may operate as a powerful stand alone device
or may be incorporated into an automated PC-based and
remotely controlled device. Includes: user manual, internal
paddle adapters, protective plates and battery eliminator.
A. DA-2006P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $3995
A precision instrument for testing defibrillators and external
(transcutaneous) pacemakers. The built-in test procedures and
extensive resistance loads for pacer testing make the
DA-2006P a versatile test instrument and solid value. Includes:
user manual, internal paddle adapters, protective plates and
battery eliminator.
Optional Accessories:
BC20-00427 Plastic Protective Plates (Set Included). $22
BC20-00432 Internal Paddle Adapters (Set Included). $42
BC20-41341 Communication Cable . . . . . . . . . . . . $90
BC20-41339 Communication Cable Adapter . . . . . $110
BC20-30108 Soft Carrying Case . . . . . . . . . . . . . . $100
Defib & Pace Adapters (for DA-2006 & DA-2006P)
B. BC20-00420 PhysioControl - Defib/Pace . . . . . . . . . $130
BC20-00421 Marquette - Defib/Pace . . . . . . . . . . . . $275
BC20-00423 Cable, Defib/Pacer Zoll . . . . . . . . . . . . $130
BC20-00426 Cable, Defib/Pacer HP/Agilent (Old Style
barrel connector) . . . . . . . . . . . . . . . . $120
BC20-00433 Cable, Defib/Pacer Test Philips (New Style)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $130
BC20-00434 Cable, Defib/Pacer Test Cardiac Science
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $130
C. DA-CS-06 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $5000
A PC based defibrillator analyzer test system for users who
wish to verify the calibration of their analyzers.
Our unique DA-CS-06 Defibrillator Analyzer Calibration
Standard system is available to qualified customers that have
a need for a defibrillator output energy standard to be used in
the calibration of their analyzers, regardless of manufacturer or
model. The DA-CS-06 was originally developed to be used in
the calibration of our own DA-2006 and DA-2006P analyzers.
D. PMT-2000 External Pacer Tester & Analyzer w/Case. Call
Evaluating and testing all Atrial/Ventricular Pacemakers includ-
ing Transthoracic Pacers. Does not adequate to test the
Medtronic 5348 and 5388 Pacers
E. BC Biomedical ESU-2000A ESU Analyzer with Kit . . $2350
Optional Accessories:
F. BC20-00120 Replacement Accessory Kit . . . . . . $130
BC20-30108 Soft Carrying Case. . . . . . . . . . . . . $100
E
E
D
D
E F I B R I L L AT O R
E F
I B R I L L AT O R
A
A
N A LY Z E R S
N A
LY Z E R S
& P
& P
A C E R
A C
E R
T
T
E S T E R S
E S
T E R S
B
A
2013-2014 Catalog
bcgroupintl.com
E
D
F
Flip for more info on this series - Pages 13-14
Flip for more info on this series - Pages 13-14
C
C
C
HECK
HEC
K
OUT
OUT
HOW
HOW
THE
THE
DA-2006
DA-2006
SERIES
SER
IES
MAK
ES
MAKE
S
AUTO
AUTO
SEQU
ENCING
SEQ
UENCING
EASY
EASY
TO
TO
DO
DO
ON
ON
PAGE
PAG
E
16
16