A. MicroMed MM-5kV Portable Electrosurgical Instrument
Insulation Detector . . . . . . . . . . . . . . . . . . . . . . $1550
McGan Technology’s MicroMed MM-5kV electrosurgical insula-
tion defect detector is a compact, hand held, battery operated
device. The MM-5kV may prevent inadvertent burns and exter-
nal skin injury which can occur during electrosurgical proce-
dures. Electrosurgical instruments may have defects (pin-
holes) in the insulation - electrosurgical instrument insulation
failure. Insulation failure happens over time, through normal
surgical use. The insulation failure provides an alternate path-
way for the current to leave the instrument's electrode and can
result in a burn. Using an electrosurgical test equipment main-
tenance program can greatly reduce the number of inadvertent
burns during electrosurgical procedures.
Application: in Facilities that do not use a large number of ESIs
over a short period of time
• Light weight portable unit
• Reusable / Interchangeable Brush or Ring electrode
• Simple operation, easy to read LCD display
• Maintains applied test voltage with constant current source
• Full test current at low voltages
• Limited Output current for operator safety
• LED displays alarm and battery charge
Accessories:
• Ground (Green) wire with Alligator clip
• Ring and Brush Electrode
B. MicroMed PD-8K Portable Electrosurgical Instrument
Insulation Detector . . . . . . . . . . . . . . . . . . . . . . $2686
McGan McGan Technology's MicroMed PD-8K electrosurgical
insulation defect detector is a portable, battery operated
device. It is used to detect and locate defects such as pinholes
and cracks in protective coatings applied over conductive
instrument's (ESI) surfaces.
Application: in Facilities that use a large number of ESIs over a
short period of time
• Operational during battery re-charging
• Simple operation, easy to read LCD display
• Multiple alarms to indicate failure
• Maintains applied test voltage with constant current source
• Limited output current for operator safety
• Regulated DC output, adjustable from 0 to 8 kV
• LCD displays provides voltage and battery charge indication
Accessories:
• Ground (Green) wire with Alligator clip and Green port
• Ring and brush electrode
• HV (Red) wire
Optional Accessories for A or B:
C. • MMTRI-0022A Tri-Hole Electrode . . . . . . . . . . $110
• MMWTU-0031 Wire continuity testing unit . . . . . . $68
D. • MMRTF-0045 RTF Test Station . . . . . . . . . . . . $310
Optional Accessories for A:
• MMRWP-0006 HV Red wire with mini-handle . . $115
• 5VEBP-0016 External rechargeable battery pack . . . . $525
• 5VACA-0015 110 volt AC Charger . . . . . . . . . . . $88