Telemetry Transmitter Installation Guide Models covered Tx300 Page 3 (Simple, 1-2-1 controller) Tx400 & Tx400DC Page 7 (1-2-1 controller) Tx1000 series MK2 Page 14 (8/16 camera matrix) Tx1000 Keypad Page 27 (Telemetry control keyboard for Tx1000 matrix) Ex4 MK2 Page 28 (System expander – control 4 TX1000 from 1 keyboard) TxLD MK2 Page 32 (RS232-RS422 converter) Building Block Video Ltd., 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU, UK.
IMPORTANT Please read the following points before servicing or installing. Pre-installation Checks - It is recommended that the unit be bench-tested prior to installation on the site. Safety During Installation or Servicing - Particular care should be taken to isolate the pan/tilt head in order to prevent operation while engineering work is being carried out.
Tx300 Simple 1-2-1 controller INTRODUCTION The BBV Tx300 is a very easy-to-use keypad for use in a single-camera CCTV system. It is easily installed into either a new or an existing system simply by connecting a BNC input and output, or twisted wire pair and a 9Vdc supply.
LAYOUT OF THE BBV Tx300 KEYPAD KEYPAD FUNCTIONS Pan and Tilt Action: Press the relevant direction arrow(s) Tx300-400-1000MK2-1000 Keypad-Ex4 MK2-TxLD Installation Guide 12Jan05.
Lens Action There are six lens-function switches on the BBV Tx300 keypad. These are Iris Open, Iris Close, Focus Near, Focus Far, Zoom In and Zoom Out. Press and hold the relevant key until the desired picture is obtained. Note: If the key is pressed and held for longer than one second, High Speed Lens Action is activated. Inching is achieved by quick presses of the key.
RANDOM PAN – Rx300 The Rx300 telemetry receivers provide a random pan feature. During Random Pan operation, the camera is randomly panned left or right for a random duration, paused for a random duration and then panned again. This adds the affect that the camera is manually controlled. During random pan, the camera can be tilted to the desired angle using the up/down buttons. Random pan is disabled by pressing either the pan right or the pan left button.
Tx400 1-2-1 controller INTRODUCTION The BBV Tx400 is a very easy-to-use keypad for use in a single-camera CCTV system. It is easily installed into either a new or an existing system simply by connecting a BNC input and output, or twisted wire pair and a 9-volt supply.
LAYOUT OF THE BBV Tx400 KEYPAD KEYPAD FUNCTIONS Pan and Tilt Action: Press the relevant direction arrow(s) Lens Action There are six lens-function switches on the BBV Tx400 keypad. These are IRIS OPEN, IRIS CLOSE, FOCUS NEAR, FOCUS FAR, ZOOM IN and ZOOM OUT. Press and hold the relevant key until the desired picture is obtained. Note: If the key is pressed and held for longer than one second, High Speed Lens Action is activated. Inching is achieved by quick presses of the key.
Auxiliary Function Switches There are four auxiliary function switches on the BBV Tx400 keypad. These are Wash, Wipe, Autopan and Lights. Their functions are as follows: WASH WIPE AUTOPAN Autopan. LIGHTS - Press and hold for washer motor to run. Latching output, press on/press off. Press, LED lights up and the Autopan motor starts. Pressing Left or Right stops - Latching output, press on/press off. SELF TEST To run Self-Test, press and hold PROGRAM whilst pressing WASH.
The remainder of this manual refers to features found only on the receivers supporting presets, Rx100 dome interface, Rx400P AC preset receiver, Rx400DC high/variable speed DC receiver and RX45X, RX55X advanced receivers. PRESETS To select a pre-programmed pre-set, press one of the Pre-set keys 1 to 8. To programme a pre-set, first position the camera using UP/DOWN and LEFT/RIGHT arrows. Then set Zoom and Focus.
STARTING THE PATROLS On starting a patrol the receiver will immediately move to the first programmed included pre-set. To start patrol 1 - Press and hold PROGRAM whilst pressing AUTOPAN. To start patrol 2 - Press and hold PROGRAM whilst pressing LIGHTS. Their function is to enable a string of presets to be selected in turn, switching between presets after a fixed period of time (nominally 30 seconds). Note: Once the nominal time period of 30 seconds has been altered, it cannot be recovered.
TO PROGRAM THE PATROL DELAY First, determine the time delay required from the table below: Pre-set Key 1 Pre-set Key 2 Pre-set Key 3 Pre-set Key 4 Pre-set Key 5 Pre-set Key 6 Pre-set Key 7 Pre-ser Key 8 - Random switching from 0 to 100 seconds 12 Seconds switching 24 Seconds switching 36 Seconds switching 48 Seconds switching 60 Seconds switching 72 Seconds switching 84 Seconds switching Press and release the pre-set key that corresponds with the delay desired, then press and hold PROGRAM whilst pressing
TWISTED PAIR OUTPUT The TWISTED PAIR output sends telemetry signals from the transmitter to the receiver. A video cable connection is still required. The normal reason for using a twisted pair option is to connect to a non-cable transmission system, fibre, microwave etc. The twisted pair output option provides a 20mA compatible output. 1200 baud 8 data bits 1 stop bit, Even parity. Simple twisted pair telemetry when not practical to use up-the-coax telemetry.
Tx1000 MK2 The system is available in four main variants: 1. 2. 3. 4. TX1000/8 MK2 8 camera inputs and 2 monitor outputs. TX1000/16 MK2 16 camera inputs and 2 monitor outputs. TX1000/8A MK2 8 camera inputs, 2 monitor outputs and 16 alarm inputs. TX1000/16A MK2 16 camera inputs, 2 monitor outputs and 16 alarm inputs. Options are available to allow control of 64 cameras using single keyboard and an EX-4 MK2 keyboard expander. Please contact BBV for further information.
Tx300-400-1000MK2-1000 Keypad-Ex4 MK2-TxLD Installation Guide 12Jan05.doc Tx1000 MK2 (8/16 camera controller) Page 15 BBV *Rx100/24/ includes 24Vac 100VA PSU. Call BBV for info. simple AC panner Rx200 Rx300 AC P/T Zoom/Focus 1 Aux. 9Vdc PSU KEYBOARD alarm cable or Security Enclosures' Videswitch can be used to transmit alarm contact over coax 9Vdc PSU Rx400P Twin Twisted Pair Optional TxLD (RS422) link. Distance 1200M max. TxLD Compatible with BBV Pick-A-Point graphical user interface.
LAYOUT OF THE BBV Tx1000 KEYPAD Connections Having mounted the base unit on the wall or in a rack, continue as follows: 1. Connect the keypad to 9-pin D socket marked "Keypad 1". 2. Connect a BNC cable from output M1 to the keypad, and connect the other keypad connection to the video monitor’s video input. Make sure that the monitor is terminated not Hi-Z. 3. If the keypad is remotely sited from the base unit, connect the 9Vdc plug-mounted power supply to the keypad via the 2.1mm power connector. 4.
CAMERA SELECTION A camera may be selected onto the controlled monitor by pressing the relevant numbered camera key, 1-16. MONITOR SELECTION The monitor key has a red LED, which is lit when the keypad is controlling the second monitor output. Pressing the monitor key toggles between controlling monitor 1 and monitor 2. SEQUENCE ACTIVATION Pressing the sequence key will start the camera sequence on the currently selected monitor.
KEYPAD FUNCTIONS The keypads should not be connected or disconnected from a "live" working unit, as this may damage the RS232 components. Priority control between two keypad systems Keypad one has priority over keypad two. If keypad one is only viewing but not operating any camera, then keypad two may move that same camera. After movement commands on keypad one, there is a 20-second or so lock-out period before control is given to keypad two.
SELF TEST To activate the self test feature for any particular camera receiver, first select that receiver, then press the Program button and select Menu Option 2. The screen text will clear and Self Test will be activated. See the Rx Series Telemetry Receiver Installation Handbook for more details. IRIS LEVEL PROGRAM To preset the aperture of the iris, press Iris Open or Iris Close until the desired level is reached, then press Program and Option 3.
The remainder of this manual refers to features found only on receivers that support presets. (Rx100, Rx400P, Rx400DC, Rx45X, Rx55X). PRESETS To select a pre-programmed preset, press the Preset key. On the screen, "Preset" will appear. While holding down the Preset key, select the desired preset number. To programme a preset, first position the camera using the Up/Down and Left/Right arrows. Then set Zoom and Focus.
2. Press Program to gain access to the menu, then press 5 to remove a preset from Patrol 1 or 6 to remove from Patrol 2, followed by the preset number to be removed. This key sequence is illustrated below. Tx300-400-1000MK2-1000 Keypad-Ex4 MK2-TxLD Installation Guide 12Jan05.
To Programme a Time Period for a Patrol First, determine the time delay required from the table below: Key 1 Key 2 Key 3 Key 4 Key 5 Key 6 Key 7 Key 8 random, 0 to 100 seconds 12 seconds 24 seconds 36 seconds 48 seconds 60 seconds 72 seconds 84 seconds Key 9 Key 10 Key 11 Key 12 Key 13 Key 14 Key 15 Key 16 96 seconds 108 seconds 120 seconds 132 seconds 144 seconds 156 seconds 168 seconds 180 seconds SPARE OUTPUTS – ALLOW CONTROL OF SPECIAL RECEIVER FUNCTIONS Four additional spare functions are provided
Tx1000 Series Alarm Input Option Alarm Inputs Alarms activate on opening of contacts. Connect each alarm pair to a volts free contact. G N D 1 G N D 2 G N D 3 G N D 4 5 G N D 6 G N D 7 G N D 8 G N D 9 Normaly closed inputs, opening for alarm. G N D 1 0 G N D 1 1 G N D 1 2 G N D 1 3 G N D 1 4 G N D 1 5 G N D 1 6 Each input has 56K internal pull-up to +12Vdc Alarm output A set of volt free changeover contacts are provided as an output from the alarm package.
ALARM CONTACTS Installer fitted keyswitch to control alarm package The alarm package may be enabled/disabled via a keyswitch fitted across alarm contacts pins 1 and 2. When the switch is closed the alarm package is disabled, opening the switch and the alarm package is active. This may be used to control the alarm package, i.e. enabled at night when the building is empty etc. Any receiver local alarms will NOT be disabled using this link.
RS485 TELEMETRY The TX1000 MK2 matrix has a single RJ45 connector that is used to control BBV RS422 telemetry receivers or a range of 3rd party receivers and dome cameras via a STARCARD/CONVERTER. It is recommended that a RJ45 breakout box and cat5 patch cable be used to connect to the telemetry connector although the breakout box isn’t essential.
TX/TPO/MK2 20mA TWISTED PAIR TELEMETRY OPTION The TWISTED PAIR option sends telemetry signals from the transmitter to the receiver. A video cable connection is still required. The normal reason for using a twisted pair option is to connect to a non-cable transmission system, fibre, microwave etc The twisted pair output option provides a 20mA compatible output. 1200 baud, Even Parity, 8 data bits, 1 stop bit.
TX1000/KBD keyboard 1. Connect monitor output from base unit to monitor via keypad. This is a passive, high impedance link for text insertion. Ensure that the coax cable is terminated at the monitor. 2. Connect the 9-pin D connector to the relevant keypad socket on the main unit: Monitor 1 - Keypad 1 Monitor 2 - Keypad 2 3. One unit may be powered from the main unit via the connector. In remote situations, however, or where a second keypad is used, a "plug lump" power supply is used.
EX4 MK 2 System Expander 1. EQUIPMENT CONTENTS EX4. 1 4 1 EX-4 Expander RS232 cables, EX-4 to Tx1000 Base Units This Installation Manual 2. INTRODUCTION GENERAL The EX-4 Keypad Expander is designed to allow a single Tx1000 keyboard to control up to four Tx1000 base units. 64 Cameras can be selected and controlled when all four base units are connected. The EX-4 is supplied in a 19" rack mountable enclosure.
3. INSTALLATION All necessary cables are provided with each EX-4 to connect to four base units as shown below. Each base unit requires a RS232 connection to it's keypad connector and also coax from monitor output to EX-4/8. Base unit number 1 supplies power for the EX-4, to maintain a low resistance path do not extend this RS232 cable. The other RS232 cables can be extended up to 50M. Should a greater distance be require, then a TxLD can be used to allow operation 500M between EX-4 and base unit.
4. OPERATION Operation is transparent. Each base unit is selected using the following key presses: Press and HOLD '#' Tap '1 - 4' (Base unit 1 - 4) Release '#' Further key presses will pass to this base unit as normal. To aid with identification of selected base unit and camera, the camera number is prefixed with 'A' - 'D' representing selected base unit. Example: Assume that four Tx1000/16 base units are connected to the EX-4.
5. EXAMPLE SYSTEM DIAGRAMS Each example assumes that both RS232 and video are connected between each base unit and the EX4. Camera 1 Camera 16 Camera 17 Tx1000/16 MK2 Camera 32 Tx1000/16 MK2 Spot monitor. Cameras 1-16 Camera 48 Camera 49 Tx1000/16 MK2 Spot monitor. Cameras 17-32 Control Monitor. Cameras 1-64 Camera 64 Tx1000/16 MK2 Spot monitor. Cameras 33-48 Spot monitor.
TxLD RS232-422 converter and keyboard line driver The kit should contain, 1 x DB9F – DB9F cable (SA-PL61-1), TxLD to Tx1000 matrix 2 x TxLD units 4 x double sided sticky pads (for mounting boxes) Technical Specification Power Requirements 9-12V ac/dc Max Load <50mA at 12V Input RS232 3 wire, Tx/Rx/Ground, DB9F Outputs RS485 twin twisted pair, Green IMO connector. Facilities Pre-made cable provided to connect to Tx1000 base unit. TxLD powered from matrix at the base unit.
TxLD WIRING INSTRUCTIONS. TxLD(B) Base Unit End TxLD(K) Keyboard End Twin Twisted Pair connection between the TxLD mk2 units. Matrix End After connecting the twin twisted pair cable to the green IMO connector mount the TxLD to a wall if required and connect to the Tx1000 base unit keypad 2 connector with the serial lead supplied (SA-PL61-1). The TxLD does not require a power supply, it obtains its supply from the Tx1000 Base Unit.
– blank for your notes –
– blank for your notes –
Other BBV products Product Description camera desktop telemetry transmitter with coax & 20mA TX300 Single telemetry, Pan/Tilt/Lens & Lights TX400 As TX300 inc Wash, Wipe, Autopan, 8 presets, preset patrol. TX400DC As TX400 including joystick for proportional Pan/Tilt control. or 16 camera, 2 monitor telemetry transmitter. Up to 2 TX1000 8keyboards and options for alarm inputs and 20mA telemetry. Mid size matrix 16 – 96 camera, 8 monitor.