RX100/BAX Installation Guide Building Block Video Ltd 17 Apex Park Diplocks Industrial Estate Hailsham, East Sussex, BN27 3JU, UK Tel: + 44 (0) 1323 842727 Fax: + 44 (0) 1323 842728 Support: + 44 (0) 1323 444600 www.bbvcctv.
CONTENTS 1. Pre-installation Checks and Safety Procedures Unpacking Important safety precautions 3 3 4 2. Introduction General RX100 Technical specification Cable connection method Fig. 1 Cable connectors 5 5 5 6 3. Installation 7 Operating voltage 7 RX100 connections 7 Fig. 2 RX100 pcb connections 4. Setup Diagnostic aids Cable length compensation Fig. 3 Launch amplifier 8 8 8 BBV RX100/24 Supply Additional Information (iss. 6 pcb) 9 5.
1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES UNPACKING Check packaging - On delivery of the unit inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Check contents - Unpack the unit carefully and check that all the items are present and correct. If any items are missing or damaged, contact your equipment dealer. Retain packaging - The shipping carton is the safest container in which to transport the unit.
Damage requiring service - Servicing by qualified personnel should be carried out under the following conditions: (a) When the power supply cord or plug is damaged (b) If liquid has been spilled or objects have fallen into the unit (c) If the internal electronics of the unit have been exposed to rain or water (d) If the unit does not operate normally by following the operating instructions.
2. INTRODUCTION GENERAL The RX100 telemetry interface is designed to allow control of a variety of integrated dome cameras using Baxall’s range of up-the-coax telemetry transmitters. (See appendix A for a complete list of supported domes.) The RX100 interface is supplied in an IP67 rated enclosure. It will be necessary to make suitable holes in the enclosure to permit cable entry and exit.
CABLE CONNECTION METHOD Fig. 1: cage clamp connectors The cage clamp PCB terminal block is a simple to use method of attaching cables to PCBs quickly and easily. Prepare cables as follows: • • Use only cable between 0.08 and 2.5 mm² Strip the cable to a length of 5 - 6 mm (0.23 in) The correct method of attachment is as follows: 1. Press down the relevant terminal block lever with a suitable screwdriver 2. Insert wire 3.
3. INSTALLATION OPERATING VOLTAGE The RX100 requires all connections to the PCB to be made by the installer, and via terminal blocks or by plug and socket. These connections are: power in, video in, video out, and serial data to dome. In addition connections for alarm in, alarm out and lights if required are provided. See Fig.2 below for correct connections. The RX100 is supplied pre-configured to suit the application for which it is intended, i.e. to control an integrated dome camera.
4. SETUP DIAGNOSTIC AIDS Two red LEDs and one Green LED are mounted on board to give simple system status information.
Example System Video Data 250M-RG59 500M-CT125 Alarm contact Rx100 Interface 9V PSU MONITOR Vista Columbus VC04Te 12V PSU RX100/BAX Installation Manual 1.
BBV RX100/24 Supply Additional information (iss. 6 pcb) The RX100/24 can be powered from either 230V ac or 24V ac. The diagrams below shows the connections that should be made for each supply voltage. Please note that when powered from 24V ac the 230V ac terminals will be at mains voltages. To prevent the risk of shocks the fuse must be removed from the fuse holder and no connections made to L and N. The 24V ac supply must be fused with a 315mA to protect the supply wiring. Fig 9. RX100/24 iss.
Appendix A - Dome addendums & connection details Bewator Solaris Dome (Pelco P at 4800 Baud) 12 JVC TK-C655B/675B/676 13 Panasonic WV-CS850/860/960 14 - 15 Pelco Spectra dome & Esprit head (P protocol) 16 Sensormatic speed dome (RS422 Only) 17 VCL-TP 18 RX100/BAX Installation manual V1.
Bewator Solaris Dome Addendum to manual for the following dome: Bewator Solaris (P-mode 4800 Baud RS485 protocol) RX100 software BB1V1 Application Notes Variable speed Pan/Tilt Zoom/Focus, Auto focus 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 - 4 Advanced Features Display dome menu Enter within menu (Goto Preset 3) Vista Columbus VC04Te Goto Preset 25 Goto Preset 26 Baxall ZT6 N/A (supports 8 presets only) N/A (supports 8 presets only) Menu access: Use ‘Goto Preset 25’ to
JVC TK-C655B/675B/676 Addendum to manual for the following dome: JVC TK-C655B/675B/676 combination cameras RX100 software BJ2V3 Application Notes Variable speed Pan/Tilt Zoom/Focus, Auto focus can be enabled/disabled from the dome menu 16 Full scene presets.
Panasonic WV-CS850/860/960 Addendum to manual for the following domes: Panasonic WV-CS850 / 860 / 960 RX100 software BP1V1 Application Notes Variable speed Pan/Tilt Zoom/Focus, Auto focus, Iris Open/Close 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 – 4 Autopan/Patrol learn play using autopan key Advanced Features ENTRY/EXIT dome menu SET (select menu item) ESC (back to previous menu) Vista Columbus VC04Te Goto preset 25 Goto preset 26 Goto preset 27 Baxall ZTX6 N/A (supports
Dome switch settings: The following procedure must be followed to ensure the correct 4 wire RS485 Protocol, Baud Rate & Address Camera Mounting Base Camera Mounting Base Fixing Screw Loosen and Push Three switch settings are used to configure the dome to work with BBV Rx100 units. For each switch setting, the dome must be de-powered and removed from the base. The switches will be set as shown below. Install back on the base and apply power. NOTE: THIS MUST BE CARRIED OUT FOR EACH SWITCH SETTING.
Pelco Spectra Addendum to manual for the following dome: Pelco Spectra (P-mode RS485 protocol) Rx100 software BP2V1 Application Notes Variable speed Pan/Tilt Zoom/Focus, Auto focus 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 - 4 Dome Pattern definition and playback Advanced Features Display dome menu Enter within menu Pattern define start Pattern define stop Vista Columbus VC04Te Goto preset 25 Goto preset 26 Goto preset 27 Goto preset 28 Baxall ZT6 N/A (Supports 8 Presets On
Sensormatic Speed dome Addendum to manual for the following domes: Sensormatic Speed dome Rx100 software BS3V1 Application Notes Variable speed Pan/Tilt Zoom/Focus, Auto focus, Iris Open/Close 7 full scene presets 4 alarm inputs driving to preset 1 – 4 Pattern 1 define – play using Autopan key Advanced features Start/Stop Pattern 1 Definition* Dome menu Vista Columbus VC04Te Goto preset 25 Goto preset 28 Baxall ZT6 N/A (Supports 8 presets only) N/A (Supports 8 presets only) *Press AUTOPAN to Run Pattern
VCL TP Protocol Addendum to manual for the following domes: VCL TP protocol Microsphere/Orbiter range. Rx100 software BV1V1 Application Notes Variable speed Pan/Tilt Zoom/Focus, Auto focus following a Zoom In/Out 16 full scene presets Fast Preset Tour. Started by pressing 1 Patrol Slow preset tour.
Appendix B - Trouble shooting guide Symptom: No video from interface Possible causes: Camera is not powered or not connected to ‘CAMERA’ BNC on interface. Check power and cabling. Interface is not powered. Check power. Video out not connected to ‘TELEMETRY’ BNC on interface. Check cabling. If the after following the above check list video still not present then remove both BNCs from the interface and connect together using a female to female barrel connector to check video path from camera to control point.
Extend your BBV Warranty from 12 months to 3 years As of the 1st September 2008 BBV have offered our customers the opportunity to extend the standard 12 month warranty to 3 years. You must register for the extended warranty within 12 months of the date of manufacture. How to register for the 3 year warranty Registering for the new, longer 3 year warranty term is quick and easy.