Service manual

– 19 –
KDF-E42/50A11E
RM-ED002
42
GB
6
Pull out the lamp.
Hook a finger through the loop of the lamp handle and pull the handle upwards. Then pull the lamp straight out..
Tips
The lamp is very hot immediately after use. Never touch the glass portion of the lamp or the surrounding parts.
After the used lamp has cooled, place it into the empty box of the replacement lamp. Never put the used lamp into
a plastic bag.
7
Put the new lamp into its place.
Mount the new lamp securely. Failure to do so may cause a fire or the screen to go dark.
Tip
If the lamp is not securely reattached, the self-diagnostic function may be triggered and the POWER/STANDBY
indicator flashes three times (see page 9).
8
Reattach the lamp door.
Turn the knob back to CLOSE and secure the cover.
43
GB
Additional Information
9 Put the outside lamp cover back in its place.
Tips
Consult your Sony dealer for a Sony XL-2400 replacement lamp.
Take great care when replacing the lamp or plugging in/unplugging the connecting cords. Rough handling may cause
the TV to fall, damaging the TV, the TV stand and the floor.