Owner`s manual
64
The Serial Port Destination for the terminal ports on each
TX104 should be configured as follows:
TX104 SERIAL PORT DESTINATIONS FOR
EXAMPLE "STAR" APPLICATION
TX104-X
Unit X
(Ports 1-4)
Serial Port Destination
Unit Modul
e
Ports
1511-4
2521-4
3531-4
4541-4
The Serial Port Destination for each TX104 may be configured
locally from each unit or remotely from the TX60 once the TX60
has been configured and the composite modules have been
connected to the respective TX104 composite ports (see Step
5).
2. Refer to the documentation for the TX60. Access Local Unit
Configuration mode for Module 1 and change the Unit Number
from "1" to "5". Exit to the System Menu.
3. Access Local Unit Configuration for Module 5 (Composite 1)
and add Unit 1 to the Multiple Unit Configuration. Likewise,
add Unit 2 to the Multiple Unit Configuration for Module 6
(Composite 2), Unit 3 for Module 7 (Composite 3), and Unit 4
for Module 8 (Composite 4). If using modems for connection to
the remote TX60, change the line type to "Modem" and
configure the Programmable Strings if desired.
4. Access Local Unit Configuration mode for Module 1 through
Module 4 and change the Serial Port Unit Destination number
for each individual port to Unit 1 for ports on Module 1, Unit 2
for ports on Module 2, Unit 3 for ports on Module 3 and Unit 4
for ports on Module 4.