Owner`s manual
62
In this application, ports on Unit 1 will communicate with respective
ports on Unit 2. Use the following guidelines to configure each unit for
this application:
1. Connect a terminal to Port 1 of the TX104 that will be located
at the site with the terminals (Unit 2). Access System mode by
typing +++. Access Local Unit Configuration mode and change
the Unit Number from "1" to "2" (see
Section 5.7
). If using
modems to connect to Unit 1, change the Line Type to
"Modem" (see
Section 5.8
) and configure the Programmable
Strings if desired (see
Section 5.5
and
Section 4.2.2.3
.).
2. Connect a terminal to Port 1 of the TX104 that will be located
at the main frame site (Unit 1). Access Local Unit
Configuration mode and change the Destination Unit for each
port to "2" (see
Section 5.6
). If using modems to connect to
Unit 2, change the Line Type to "Modem" and configure the
Programmable Strings if desired.
3. Connect the composite ports of each TX104 together via
modem or cable (see
Section 3.5
.).