Owner`s manual
60
If you wish to change the baud rate for the composite port to 38,400
bps, enter "D" in response to the prompt and the Telplex will respond
with the reconfigured status of the port, the option menu, and the
prompt as follows:
+------+------+------+------+------+--------+
| Port | Baud | Word | Stop |Parity| Line |
| | Rate | Size | Bits | | Type |
+------+------+------+------+------+--------+
| 5 | 38400| 8 | 1 | None | Direct |
+------+------+------+------+------+--------+
Exit/Save......1
Set Baud Rate..2
Line Type......3
Enter Request:
If you wish to change the Line Type of the Telplex, type "3" in
response to the prompt. The Telplex will respond with:
1 For Modem
2 For Direct
Enter Request or X to Exit :
Enter the number corresponding to the desired Line Type.
IMPORTANT: If you intend to connect an external modem to the
composite port, you must choose
Modem
Line Type. If you choose
Modem Line Type, keep in mind this does not configure the external
modem to communicate with a dial or leased line. If you intend to
connect the Telplex via cable, you must choose
Direct
Line Type.
If the baud rate and/or Line Type is acceptable, type "X" (Exit/Save)
and the Telplex will respond with:
Save Baud Rate Changes Permanently ? (Y/N):
If you enter "Y", the new baud rate for the composite port will be
stored permanently in non-volatile memory and the Telplex will
subsequently power up at that configuration. If you enter "N", the new
baud rate will be stored in RAM and on the next power-up, the Telplex
will revert to the previous configuration.