Owner`s manual
33
Diagnostics mode for a standard unit is accessed from the Remote
Configuration Mode menu. This menu is accessed from the Local
Mode menu (see
Section 4.3.1
) by tying
Control-R
from the active
terminal. The Telplex will respond with the Remote Configuration
Mode menu as follows
Communicating to Remote Unit, Enter ^X to Cancel
Bay Technical Associates
Model TX108 Statistical Multiplexer
Copyright 1990-1992
Revision 1.04
Remote Configuration mode
Status......................................1
Serial Port Configuration...................2
Block Size, Local Access & Status Messages..3
Run Diagnostic..............................4
Programmable Strings........................5
Exit........................................X
Enter Request:
Type "4" in response to this menu (Run Diagnostic) and the Telplex
will respond with the "Run Diagnostic" menu as follows:
Self-Test........................................1
Full duplex communication to a select port.......2
Loop Back communication on a select port.........3
Exit.............................................X
Enter Request:
Select the desired diagnostic. For example, if you type "1" (Self-Test),
the Telplex will perform diagnostics on various components of the
remote unit. While the self-test is in progress, the local unit will send
the following message:
Please wait while self-testing...
If the remote unit passes its self-test, the Telplex will send back the
following message:
Self-test passed