Owner`s manual

32
If you type "2" from the Local Diagnostics Menu (Self Test
Diagnostics), the Telplex will perform a self test on all local ports and
will respond with the results shown below:
Self Test Module on Local Unit
Z passed
RAM passed
EPROM passed
UART passed
PORT 4 passed
PORT 3 passed
PORT 2 passed
PORT 1 passed
Once the self test has been completed, the Telplex will return to
System mode and display the System Menu. If you get a "failed"
message after any of the tests, call BayTech at 1-800-523-2702.
NOTE: The TX108 will only display that Ports 1 through 4 have
passed the self test diagnostic. The menu above will show if Port 5
through Port 8 have failed if there is a failure on any of these ports
and there is no failure on Port 1 through Port 4.
If you wish to run the loopback diagnostic, type "3" from the "Local
Diagnostics Menu" or "Remote Diagnostics Menu" (Loopback Data
On Selected Port) and the Telplex will respond with a prompt to enter
the desired port number. Type the desired port number. For
example, if you type "2" for Port 2, the Telplex will respond with:
Connected To Port 2, Type Ctrl X to exit to System Menu
NOTE: If you are performing remote diagnostics on Unit X (X = 1 to
32), Module Y (Y = 1 to 16), this menu will shown the following:
Connected to Unit 00X, Module 00Y, Port 002
Type +++ to Return to System Menu
At this point you may do loopback communication with Port 2.
Anything you type will be echoed back to your terminal screen by Port
2 and will also be sent to the device connected to Port 2. If
performing local unit diagnostics, type
Control-X
to terminate this
diagnostic or +++ if performing remote unit diagnostics. In either
case, the Telplex will return to System mode.