If Local mode is currently accessed by another terminal port, the
Telplex will send the following message:
Local Mode Currently Being Accessed by another Port
Local and Remote Unit Configuration mode are used to program the
various features of the local Telplex or a remote unit. For multi-drop
units, Local Unit Configuration mode is accessed by typing "1" from
the System Menu and Remote Unit Configuation mode is accessed by
typing "2" from this menu. For standard units, Local Unit
Configuration mode is accessed by typing
Control-T
from the Local
Mode menu and Remote Unit Configuration mode is accessed by
typing
Control-R
from this menu.
NOTE: The active terminal may access Remote Unit Configuration
mode only if there is a communication link established with the
desired remote Telplex. The active terminal cannot change any
features of the remote unit's composite port since this would disrupt
the communication link.
Programmable features for the terminal ports include serial port
configuration, Data Block Size, and Status Messages. Serial Port
Destination and Unit Number are programmable for multi-drop units
only. Programmable features for a local composite port include baud
rate, Line Type, Programmable Strings and Multiple Unit
Configuration.
Section 5
provides a detailed description of how the local Telplex or a
remote unit is programmed while in Local Unit or Remote Unit
Configuration mode.