Owner`s manual
12
The composite ports of multiple Telplex units are connected together
via external modems (
Section 3.5.1
) or cable (
Section 3.5.2
).
See
Section 3.5.1.1
if connecting a modem to a TX104 or TX108 or
Section 3.5.1.2
if connecting a modem to a TX102.
If an external modem will be used to connect a local TX104 or TX108
to a remote Telplex, the modem should be connected to the
COMPOSITE EIA-232
port on the back panel of the unit (see
Appendix B
). The TX104 or TX108 should be programmed to operate
with a Line Type of Modem (see
Section 5.8
).
The standard configuration of the
COMPOSITE EIA-232
port is DTE
(Data Terminal Equipment) with a DB-25 male connector which uses
the following signals for communication:
TX104 AND TX108 EIA-232 COMPOSITE PORT PIN/SIGNAL DEFINITION
Pin Signal
(EIA-232)
Direction Description
1 PGND --- Protective Ground
2 TX Output Data Out
3 RX Input Data In
4 RTS Output +12 volts when Telplex is powered up
5 CTS Input Transmit enabled when +12 volts. Enabled if no connection.
7 SGND --- Signal Ground
8 DCD Input Data Carrier Detect. Controlled by modem.
20 DTR Output +12 Volts