Owner`s manual

17
Serial ports on the Model 24's MOD 4CF I/O module have DB-25
female DCE connectors. DCE ports use the following signals for
communication:
DCE PORT PIN/SIGNAL DEFINITION
Pin Signal
(EIA-232)
Direction Description
1 PGND --- Protective Ground
2 Tx Input Data In
3 Rx Output Data Out
4 RTS Input Internally Enabled if No Wire Connected (Normally Not Used).
5 CTS Output -12V When Buffer is Full
6 DSR Output +12 V When Model 24 Powers Up.
7 SGND --- Signal Ground
8 DCD Output +12 V When Model 24 Powers Up.
20 DTR Input Transmit Enabled When +12 V.
If you are interfacing a DCE device to the Model 24 (DTE), you must
use a one-to-one or straight cable as shown in
Figure 2
on the following
page. If you are interfacing a DTE device to the Model 24 (DTE), you
must use a crossed cable as shown in
Figure 3
.
When using XON/XOFF protocol, it may be desirable to use cables with
only Tx, Rx and SGND (signal ground) connected. On the serial ports
of a BayTech Model 24, input handshaking lines are enabled if nothing
is connected, allowing the system to operate with only Tx, Rx and
SGND connected.
CAUTION: Do not attempt to use a serial cable on a parallel port.
Since an EIA-232 serial port usually carries a potential of +12 and -12
volts, plugging a serial cable from that port into a parallel port may
cause damage to the parallel port.