Owner`s manual

70
The table below provides a list of parameters supported by the
BCON command utility. These parameters apply to Print Servers
Plus models only.
BCON.EXE COMMAND LINE PARAMETERS
Command Parameter Description
RESET Resets the specified print server
NA=new name Assigns a new name to the specified print server
MO=AU,xx Sets print server to automatic operation update mode with the
time interval set to xx minutes
MO=MA Sets print server to manual operation update mode
Px=baud rate,parity,data bits,stop bits,
handshake mode
(Not applicable for PS-4A or PS-MIO)
Sets print port x (x = 0, 1, 2, or 3) to the desired serial
parameters. Please see
Section 2
for a list of available serial
parameters. The handshake parameter may be set to "N" for
no handshaking, "X" for XON/XOFF, or "D" for hardware.
EXAMPLE: If you wish to rename a BayTech print server with a
default name of
BT-053AB0
to
PRINTSERVER-1
, you would enter
BCON BT-053AB0 NA=PRINTSERVER-1
.
NOTE:
When renaming your BayTech print server, you must use
the standard Novell naming convention. Please see your Novell
documentation for legal characters.
EXAMPLE: If you wish to reconfigure Port 1 of
PRINTSERVER-1
to 460,800 bps, no parity, 8 data bits, 1 stop bit, and XON/XOFF
handshaking, you would enter
BCON PRINTSERVER-1 P1=460800,N,8,1,X
.