Owner`s manual
42
CAUSE: Port selection.
SOLUTION: Be sure host device is connected to the
host port (Port 1) on the Model 24H.
CAUSE: Software.
SOLUTION: Use dumb terminal or a computer
running a terminal emulation program (i.e., TERM
supplied by BayTech, or another communications
package).
CAUSE: Bad serial port on host computer.
SOLUTION: Try a different serial port or host device.
PROBLEM: GARBAGE DATA
SYMPTOM: MISSING CHARACTERS
CAUSE: No data flow control due to incorrect cable
type.
SOLUTION: Check hardware handshaking lines in the
cable. The CTS is the input flow control line and
DTR is the output flow control line. Determine
which flow control signals are defined as input and
output for your equipment. Connect the CTS line
to the signal defined as output and DTR to the
signal defined as input. If using XON/XOFF
handshaking, verify that both Tx and Rx are
connected in the cable. Also verify that
XON/XOFF handshaking is enabled on the Model
24H and that your equipment supports XON/XOFF.
CAUSE: Cable length.
SOLUTION: BayTech will guarantee EIA-232 serial
data transmission up to 150 feet at 9600 baud. If
your cable exceeds this length, either shorten your
cable length or reduce the baud rate.