Owner`s manual
36
By responding to the Enter Request: message at the end of the
configuration menu (see
Section 6.1
) with "6" (Change Message
Terminate Character), you may custom set the terminating character
for Modes of Operation 2, 3, 4 and 5. The Model 24H will respond with:
Current Terminate Character is.............0DH
Enter Terminate Character in Hex
or ENTER for no change ....................:
Enter the terminating character that you wish in the form of a two-digit
hexadecimal character. For example, if you enter "0A" (Line Feed), the
data exchange system will respond with:
Current Terminate Character is.............0AH
Save Changes Permanently? (Y/N):
If you answer "Y" (yes), the new terminating character will be stored
permanently in non-volatile memory, and the Model 24H will
subsequently power-up with the new terminating character in effect. If
you answer "N" (no), the new terminating character will be stored in
RAM and lost upon next power-up. The Model 24H will now return to
the main configuration menu.