Owner`s manual

30
Enter "8" for 38400 baud rate, and the Model 24H will respond with the
reconfigured status of the port, the option menu, and the prompt:
+------+------------------+-------+------+------+------+------+------+
| Port | Logical Name | Baud | Word | Stop |Parity| Xon / Xoff |
| | | Rate | Size | Bits | | Xmit | Recv |
+------+------------------+-------+------+------+------+------+------+
| 7 | Device D | 38400 | 8 | 1 | None | Off | Off |
+------+------------------+-------+------+------+------+------+------+
Exit/Save......1 Set Stop Bits.....4
Set Baud Rate..2 Set Parity........5
Set Word Size..3 Set Xon/Xoff......6
Enter Request :
You may now select other options from the menu to reconfigure Port 7.
For example, to set XON/XOFF, type "6" (Set Xon/Xoff) in response to
the prompt. Note that Output Flow Control and Input Flow Control are
set separately for each port. The Model 24H will respond with:
Output Flow Control (Xmit) - Xon/Xoff is ( Off )
Stop/Restart Output Upon Receiving of Xoff/Xon ? (Y/N) :
You should then enter "Y" to enable XON/XOFF on transmit, "N" to
disable XON/XOFF on transmit. For example, if you entered "Y", the
Model 24H will respond with:
Input Flow Control (Recv) - Xon/Xoff is ( Off )
Xoff/Xon sent based on Buffer - Full/Empty condition ? (Y/N) :
You should then enter "Y" to enable XON/XOFF on receive, "N" to
disable XON/XOFF on receive. For example, if you enter "N", the
Model 24H will respond with the reconfigured status of the port, the
option menu and the prompt.
+------+------------------+-------+------+------+------+------+------+
| Port | Logical Name | Baud | Word | Stop |Parity| Xon / Xoff |
| | | Rate | Size | Bits | | Xmit | Recv |
+------+------------------+-------+------+------+------+------+------+
| 7 | Device D | 38400 | 8 | 1 | None | On | Off |
+------+------------------+-------+------+------+------+------+------+
Exit/Save......1 Set Stop Bits.....4
Set Baud Rate..2 Set Parity........5
Set Word Size..3 Set Xon/Xoff......6
Enter Request :