Owner`s manual
25
Configuration changes are made through the host port which is Port 1.
Port 1 must always be a serial port to allow configuration to occur.
Once the configuration mode has been accessed, all LEDs will
illuminate and will remain illuminated while configuration is occurring.
To access the configuration mode of the Model 24H, use the following
procedure:
1. Connect a dumb terminal (or a PC running a terminal emulation
program) to Port 1. Configure your terminal's serial parameters
to match those of the Model 24H. From the factory, all serial
ports on the Model 24H are factory set at 9600 baud rate, 8
word size, 1 stop bit, no parity, and XON/XOFF disabled.
If you do not have a dumb terminal or a terminal
emulation program, BayTech supplies a utility diskette
which includes software to put an IBM PC or compatible
into a terminal mode (TERM.EXE). Please see
Section
3.2
.
2. Send from this device
Control-T
(14 Hex) followed by ASCII
capital C (43 Hex).
NOTE: If you are using the TERM.EXE program supplied on the
software utility diskette, you may depress the F1 key to send
Control-T
followed by
C
.
You should receive the main configuration menu and all the red
LEDs on the front panel should illuminate. If this does not
happen, please refer to the Troubleshooting Guide (see
Appendix A
).