Instructions / Assembly

Burner will not light
Yellow, sooty irregular
flame
Cooker lights, but
flame is very small
Flame dramatically
reduces, and LP
cylinder has frost on it.
Hissing or gurgling
sounds coming from
appliance
Flame has gone out
Burner is clean, but
still will not light
TROUBLE-SHOOTING
Symptom Cause
Possible Solution
Obstruction in the jet tube
Obstruction in the jet tube
LP tank has low fuel
LP tank has low fuel
LP tank has low fuel
Too windy
Gas Flow Limiting Device has
activated
Extended cooking on HIGH (the
liquid propane is freezing inside
the tank.
Damaged or leaking hose and
regulator assembly
Not enough gas flow from tank
LP tank has low fuel
Part of appliance is damaged
LP tank has low fuel
Damaged hose & regulator
assembly
Disconnect hose and regulator. Inspect and clean
cooker.
Disconnect hose and regulator. Inspect and clean
burner. Inspect and clean cooker.
Use a tank fill gauge to always know gas level.
If gas is too low to operate, refill or exchange tank.
Use a tank fill gauge to always know gas level.
If gas is too low to operate, refill or exchange tank.
Use a tank fill gauge to always know gas level.
If gas is too low to operate, refill or exchange tank.
Check wind direction and wait for wind to die
down, or set cooker away from windy areas.
Turn LP cylinder valve and HVR brass valve OFF.
Wait 30 seconds and repeat steps for lighting.
Turn unit OFF, and stop cooking until frost melts and
tank is no longer cold to the touch. If you return to
cooking with the same LP tank, operate with a less
intense flame.
Turn unit OFF and wait for it to cool down. Perform
Gas Leak Test to confirm gas leak. Contact Barbour
International, Inc. to replace damaged hose and
regulator assembly.
Open LP cylinder valve all the way.
Use a tank fill gauge to always know gas level.
If gas is too low to operate, refill or exchange tank.
Inspect LP tank, cooker, and HVR assembly for
damage. Contact Barbour International, Inc.
to replace damaged parts.
Use a tank fill gauge to always know gas level.
If gas is too low to operate, refill or exchange tank.
Contact Barbour International, Inc. to replace
damaged hose and regulator assembly.
Contact Barbour International, Inc. customer service at
1-800-864-6194, or visit www.thebayou.com.
17