Instructions / Assembly
Watch for Bubbles
GAS SUPPLY HOSE
GAS LEAK TEST INSTRUCTIONS
Note: The gas leak test must be performed in an area that has adequate
lighting in order to see if bubbles are developing. DO NOT use a flashlight
to check for bubbles.
1. Create a mixture of 50% water and 50% liquid dishwashing soap.
2. Turn the gas cylinder valve to the OFF position.
Then turn regulator valve to OFF position.
3. To turn ON the fuel supply, turn the cylinder valve
knob one turn in open direction. Gas will flow through
and stop at the closed regulator valve.
4. Using a clean brush, apply the soap water mixture to the following:
Cylinder Valve to Cylinder
Connection Nut to Cylinder Valve
Back side of Connection Nut to Brass Nipple
Brass Valve next to Regulator
Regulator connection to Gas Supply Hose
LP Cylinder Welds
Full length of Gas Supply Hose
Gas Supply Hose connection to Jet tube
5. Check each place A - F for growing bubbles which indicates a leak.
6. Next, turn ON brass valve to permit gas to pass
through the hose. Check each place listed for growing bubbles,
G & H, which indicates a leak. NOTE: Do not allow gas to flow
more than 5 - 10 seconds while checking for leaks, and then
turn off gas supply at the cylinder. During this process, gas will be
flowing out the jet tube into the air.
7. Turn OFF gas supply valve on LP Gas Cylinder.
8. Turn regulator valve to OFF position.
9. Tighten any leaking connections.
10. Repeat soap water mixture test until no leaks are detected.
DO NOT use cooker if gas leaks cannot be stopped.
11. After you are certain there are no leaks, turn tank valve and regulator valve
to OFF position. Wait 5 minutes for any gas fumes to evacuate before
lighting the appliance.
WARNING
WHEN TO PERFORM A LEAK TEST
• After assembling your cooker and before lighting for the first time, even if purchased fully assembled.
• Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
• Any time your cooker has been moved.
• At least once per year or if your cooker has not been used for more than 60 days.
WARNING
If growing soap bubbles persist throughout any portion
of the Gas Leak Test, terminate use immediately.
WARNING
9
WARNING