WARNING
Do not attempt to alter or disconnect the LP cylinder while the appliance is in
use.
Do not move the LP cylinder while it is connected to the appliance. Always
disconnect to move the appliance and/or tank.
This appliance is not designed to be connected to a Natural Gas Supply Line.
The hose and regulator assembly supplied with this appliance must be used.
Approved replacement parts must be obtained from Barbour International,
Inc.
If the appliance is not in use, the gas must be turned o at the supply LP
cylinder.
LP cylinders must be stored outdoors out of the reach of children, and shall not
be stored in a building, garage or any other enclosed area.
Allow only qualied LP gas dealers to properly ll or repair your LP cylinder.
Always secure the LP cylinder in an upright position.
Always use the protective cap when not connected to the hose and regulator.
Only use the cap supplied with the LP cylinder; any other type may result in
leakage of propane.
8
THERMOMETER TEST (Check before each use)
TEMPERATURE ACCURACY:
While wearing protective glove, hold the thermometer by the dial and insert stem into boiling water.
The needle should quickly move around the dial and register approximately 212°F (100°C)
(plus or minus 5°F). This indicates whether or not temperature reading is accurate.
NOTE: Due to water evaporation, the maximum reading possible on a thermometer in hot water
is 212°F (100°C).
Replace a faulty thermometer with Model# 5025.
WARNING
NEVER insert the stem of the thermometer into food. This will cause an incorrect
temperature reading.
DO NOT attempt to use your thermometer if it is not working.