Owner`s manual

M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
76
Type “4” and <cr> to enter the Sample Start Time menu. The V77 ADM-1 will
respond:
SELECT ACTIVE CHANNELS
Enter 1 to ENABLE or 0 to DISABLE each channel <cr>, or X to Exit.
NOTE: Only channels 1-8 can be active if DIFFERENTIAL inputs selected!
CHANNEL NUMBERS
1111111
1234567890123456
CURRENT STATUS 1000000000000000
ENTER SELECTION:
Type a number between 0000000000000000 and 1111111111111111 followed by
<cr>. A "1" indicates that a channel is active and a "0" indicates the channel is
inactive. You may enable or disable any individual input channel. It is not necessary
to enter all 16 channels. You have only to enter up to the highest channel you wish to
activate or deactivate. For example, if all channels are initially inactive
(0000000000000000), and you only want to activate channels one and four, enter
1001<cr>.
NOTE: Only channels 1 through 8 may be enabled if Differential inputs are
selected (i.e., channels 9-16 cannot be active). If you enter a "1" for
channels 9-16 while in differential mode, those entries will automatically
revert to "0".
If you increase the number of active channels and exceed the maximum sample rate, a
menu appears showing the maximum permissible sample rate based on the number of
active channels. For example, if you had eight active channels allowing a maximum
sample rate of 500S/sec and increased to 16 active channels, the following message
appears if you select Set Sample Rate under the Sampling Setup menu:
SET SAMPLE RATE 250S/sec
Enter Rate (1-250S/sec) followed by ENTER or X to Exit:
An entry within the displayed range must be entered, or you can exit this menu and
reduce the number of active channels.
DYNAMIC CONFIGURATION