Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
74
Type the hexadecimal representation of the desired terminating character(s). For
example, <cr> would be represented by 0D Hex.
NOTE: Only ASCII characters A-F and 0-9 are acceptable.
CHANNEL INPUT SETUP
Type “4” and <cr> to enter the Channel Input menu. The V77 ADM-1 will respond:
CHANNEL INPUT SETUP
Range 1
Unipolar / Bipolar 2
Single Ended / Differential 3
Active Channels 4
Exit X
Enter Selection:
RANGE
Type “1” and <cr> to enter the Range menu. The V77 ADM-1 will respond:
SELECT INPUT VOLTAGE RANGE
Range +/-5 or 0-10 Volts
+/-10 Volts with JP1 installed 1
+/-5 or 0-10 Volts 2
+/-2.5 or 0-5 Volts 3
+/-1.25 or 0-2.5 Volts4
+/-0.625 or 0-1.25 Volts 5
Exit X
Enter Selection:
Enter the number (1 to 5) corresponding to the desired Range.
IMPORTANT: If you intend to operate at +/- 10 volts, insure jumper JP1 is
installed before connecting inputs to the V77 ADM-1.
NOTE: A correct Unipolar/Bipolar selection must be made in conjunction
with Range selection to insure proper operation.
UNIPOLAR/BIPOLAR