Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
71
When Schedule Reporting Method is selected, the V77 ADM-1 will begin reporting
data messages at the programmed Report Start Time. The Report Start Time is
programmable up to 24 hours in advance of the current (time-of-day) clock time.
Data messages are stored in the buffer until the Report Start Time is reached at which
time all buffered data messages are reported to the host module. Further reporting is
based upon the selected Report Interval.
NOTE: When a data message is requested by entering the RAn or RSn data
commands, the Reporting and Sampling Methods currently programmed are
overridden and the data message(s) is reported. To resume the programmed
Sampling Method and Reporting Method, send the port select code followed
by <cr>.
REPORT START TIME
Type “2” and <cr> to enter the Report Start Time menu. The V77 ADM-1 will
respond:
REPORT START TIME
Reporting Start Time HH:MM
Current Date04/28/00 and Time MM/DD/YY HH:MM:SS
Enter Hours (0-24) <cr>, or X to Exit:
Enter Minutes (0-59) <cr>, or X to Exit:
This menu shows the current Reporting Start Time, Current Date04/28/00 and Time
as reported by the base unit's time-of day clock when the reporting start time entry
was selected, and prompts you to enter the desired Report Start Time. Reporting can
be delayed up to 24 hours from the current time.
Enter the desired Report Start Time. For example, suppose the Current Time is
9:20:30 and the Reporting Start Time is set to 10:45. After you exit the Configuration
Main Menu, the V77 ADM-1 will start reporting data messages at 10:45 at the
programmed Sampling Setup. If the M Series loses power, reporting resumes the
next time the designated Report Start Time is observed by the time-of day clock.
IMPORTANT: The Current Date04/28/00 and Time is not updated during
data entry. You must consider any delays from the time you enter the Report
Start Time until you exit the Configuration Main Menu. Be sure to set the
Report Start Time far enough ahead of the current time to complete all
configurations and exit configuration mode.