Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
67
SELECT SAMPLING METHOD
Sampling Method COMMAND
Command 1
Immediate 2
Schedule 3
Exit X
Enter Selection:
The V77 ADM-1 provides three Sampling Methods. These are Command (upon
request via data commands only), Immediate (upon exiting configuration), and
Schedule (where sampling begins at a specified time). When Command Sampling
Method is selected, the V77 ADM-1 will only sample when the SAn command is
issued. One data message will be read at the programmed Sampling Rate and
Number of Samples to Average and reported to the host device for each channel
specified. The SAn command may be issued to the V77 ADM-1 in any of the three
Sampling Methods.
When Immediate Sampling Method is selected, the V77 ADM-1 will sample at the
selected Sample Rate, Sample Interval, and Number of Samples to Average
immediately after exiting the Configuration Main Menu. When Schedule Sampling
Method is selected, the V77 ADM-1 will begin sampling at the programmed Sample
Start Time. Sampling will occur at the programmed Sample Rate, Sample Interval,
and Number of Samples to Average. The Sample Start Time is programmable up to
24 hours in advance of the current (time-of-day) clock time.
IMPORTANT: If you program the V77 ADM-1 to commence sampling
after the Report Start Time, data messages are not furnished until the
Sampling Start Time is reached. Conversely, if you start sampling before the
Report Start Time, the first report will contain all data sampled and buffered
until reporting is initiated.
NOTE: When a "Command" sample is requested by entering the SAn data
command, the Reporting Method and Sampling Method currently
programmed are overridden and a single data message is read and reported.
Multiple SAn commands may be entered before returning to self-reporting
operation. To resume the programmed Sampling Method and Reporting
Method, send the port select code followed by <cr>.
SAMPLE START TIME
Type “2” and <cr> to enter the Sample Start Time menu. The V77 ADM-1 will