Owner`s manual

M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
53
Type “3” (in the configuration main menu) and <cr> to change gateway. The module
will respond:
Enter Gateway address in dotted decimal form:
Enter the desired Gateway or router address as a series of four numbers separated by
periods (e.g., 197.3.14.1) followed by <cr>.
IMPORTANT: After programming the Gateway address, the M-Series unit
must be reset for the new information to take effect.
SELECT CODE
Type “4” (in the configuration main menu) and <cr> to change the select code. The
module will respond:
Enter Select Code (8 chars max):
Type the desired port select code followed by <cr>. The V72 saves the new port select
code permanently in the non-volatile memory and returns to the main configuration
menu.
NOTE: The select code is case sensitive. You cannot program the port select
code to be $BT from the service port or service modem.
NOTE: It is not necessary to reset the unit for this option to take effect.
PASSWORD
Type “5” (in the configuration main menu) and <cr> to change the password. The
module will respond:
Current password: BTA
Enter Password (8 chars max):
Type the desired password up to eight ASCII characters. Press <cr> to return to the
main configuration menu.
IMPORTANT: Record your password and keep it in a secure place. If a
password is lost or forgotten, you must contact a BayTech applications
engineer and provide authenticated authorization for the password retrieval
procedure.
NOTE: The password is case sensitive. Any non-alphanumeric character
including <BACKSPACE> and <DELETE> or a password greater than eight
characters is interpreted as an input error and you will be prompted to enter the
password again.
Terminate the password entry by typing the <cr> key. The V72 will respond with: