Owner`s manual

M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
52
Bay Technical Associates
IP Addr: 200.4.3.190 Subnet Mask: 255.255.255.0
Gateway Addr: 200.4.3.1 Select Code: $BT
Ethernet Addr: 00.C0.48.1A.24.5D ID MSG/Login: enabled/enabled
Unit Mem (MB): 16 IMR/CRT: disabled/disabled
TCP Sessions: 0 Menu/ATTN: disabled
BrkLen 350 ms Hst Cfg/RTel disabled/enabled
IP Address 1
Subnet Mask 2
Gateway 3
Select Code 4
Password 5
User Interface 6
Diagnostics 7
Exit X
NOTE: The Unit Mem (MB) line, showing the amount of memory is
displayed only if an M03 memory module is installed.
You can now make whatever changes are necessary by responding to the above menu.
The "X" selection (Exit Configuration) will return you to the operations mode.
IP ADDRESS
Type “1” (in the configuration main menu) and <cr> to change the IP address. The
module will respond:
Enter IP address in dotted decimal form:
Enter the desired IP address as a series of four numbers separated by periods (e.g.,
197.3.14.9) followed by <cr>.
IMPORTANT: The IP address must be programmed before the V72 module
can be accessed on the network. After programming the IP address, the M-
Series unit must be reset for the new information to take effect.
SUBNET MASK
Type “2” (in the configuration main menu) and <cr> to change the subnet mask. The
module will respond:
Enter Subnet Mask in dotted decimal form:
Enter the desired Subnet Mask as a series of four numbers separated by periods (e.g.,
255.255.255.0) followed by <cr>.
IMPORTANT: The Subnet Mask must be programmed before the V72
module can be accessed on the network. After programming the Subnet Mask,
the M-Series unit must be reset for the new information to take effect.
GATEWAY