Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
49
Port Select Code is:$BT
Enter Port Select Code (Max. 8 Characters)
and ENTER when done:
Type the desired port select code followed by <cr>. For example, if you type #PORT
followed by <cr>, the V71 will respond with:
Port Select Code is:#PORT
Enter Port Select Code (Max. 8 Characters)
and ENTER when done:
If no additional change is desired, type <cr>. The V71 saves the new port select code
permanently in the non-volatile memory and return to the main configuration menu.
NOTE: You cannot program the port select code to be $BAYTECH from
the service port. If you wish to use $BAYTECH as the port select code, you
must program the port select code from the V71 host module.
SERIAL PORT CONFIGURATION
Type “3” and <cr> to enter the serial port menu. The V71 will respond:
Xon / XoffPort Baud
Rate
Word
Size
Stop
Bits
Parity
Xmit
Recv
Line
Interface
1 9600 8 1 None Off Off EIA-232
Exit/Save 1 Set Stop Bits 4 Set Line Interface 7
Set Baud Rate 2 Set Parity 5
Set Word Size 3 Set XON/XOFF 6
Enter Request :
You can now reconfigure the V71 by selecting the appropriate option from the menu
(1 to 7). For example, to change the baud rate to 115.2K baud, send "2" (Set baud
rate). The V71 will respond with this menu:
1 for 50
2 for 75
3 for 110
4 for 135
5 for 150
6 for 300
7 for 600
8 for 1200
9 for 2400
A for 4800
B for 9600
C for 19200