Owner`s manual

M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
44
BASE UNIT AND MODULE CONFIGURATION
BASE UNIT CONFIGURATION
The base unit can be configured from the service port, the service modem, or a host
control module.
NOTE: Once the date has been programmed, the base unit will
automatically adjust for months having 28, 29, 30, or 31 days for all years up
to 2087. The base unit also tracks the correct day of the week automatically.
HOST MODULE, SERVICE PORT, AND SERVICE MODEM
CONFIGURATION (CONFIGURATION PORTS)
To access configuration mode of the base unit from one of the configuration ports,
use one of the following procedures.
NOTE: The configuration ports will not respond to commands for
approximately 15 seconds after the unit is powered up or reset.
HOST MODULE ACCESS
1. Connect a terminal to the host module and access the base unit
configuration menu using either the menu mode:
a) Select configuration mode by typing ā€œCā€ followed by <cr>
at the main prompt ;
b) and type the number of of the base unit (varies with
number of module slots avaialable), followed by <cr>.
or the dynamic configuration mode.
a) Connect to the base unit by sending the port select code
($BT - default), 0, and <cr>.
NOTE: Substitute module number (1-16) for base unit number (0) to
configure other modules.
b) Access configuration mode by sending $CONFIG<cr>.
For example, if using the default port select code, send
$BT0<cr>$CONFIG<cr> to enter into configuration mode