Owner`s manual
M SERIES DAC
CABLING
____________________________________________________________________________
28
Ground 1 14 Ground 1
10 & 22
Ground 2 15 Channel 16 2
9 & 21
Channel 8 3 16 Channel 15 3
8 & 20
Channel 7 4 17 Channel 14 4
7 & 19
Channel 6 5 18 Channel 13 5
6 & 18
Channel 5 6 19 Channel 12 6
5 & 17
Channel 4 7 20 Channel 11 7
4 & 16
Channel 3 8 21 Channel 10 8
3 & 15
Channel 2 9 22 Channel 9
+ -
Channel 1 10 23 Ground
Polarity
Ground 11 24 Ground
Ground 12 25 Ground
Ground 13
Single-ended Input Connection Differential Input Connections
IMPORTANT: If you are connecting multiple single-ended devices, it is
imperative all the grounds returns are at the same potential or erroneous
operation could result. If a channel is not connected to an external circuit, it
should be terminated to ground or programmed as inactive (see Section
5.1.5.4). This prevents the presentation or reporting of erroneous data from
unused inputs.
V78 Pinout
The V78 CRM-1 is installed in the M Series chassis as described in the installation
section of this manual.
NOTE: The V78 CRM-1 cannot be installed as Module 1. If a V78 CRM-1
is removed from a module slot and a different V78 CRM-1 is installed in that
location, the newly installed module acquires the previous module's
configuration. Moving an V78 CRM-1 to a different module location
requires reconfiguration because the configuration parameters are stored as a
function of slot location and module type. The configuration information
does not stay with a relocated module.