Owner`s manual
M SERIES DAC
CABLING
____________________________________________________________________________
21
Refer to the following modular adapter drawing (Figure 35) to interface modems to
the V74 or V75 module.
Refer to the modular adapter drawing (Figure 36) below to connect an EIA-232 serial
printer to the V74 or V75 module.
IMPORTANT: When BayTech modular adapters are used as given in
Figures 31-36, a crossed 8-wire modular cable is required. Do not use 4-
wire modular cabling.
14.1.5 V75 EIA-422 CABLING
The cable required to connect an EIA-422 device to the V75 module using EIA-422
serial interface must have TX+ wired to RX+ (and vice versa), TX- wired to RX- (and
vice versa), HSO wired to HSI (and vice versa), and the grounds connected. Please
see Figure 37.
V75 (EIA-422) Equipment
RJ-45 Connections
1 HSO HSI
2 GND GND
3 TX+ RX+
4 TX- RX-
5 RX- TX-
6 RX+ TX+
7 GND GND
8 HSI HSO
Figure 37: V75 EIA-422 Connection
Insert the 25 pin
md4 adapter
Insert the 25 pin pr2 adapter
Insert the crossed cable drawing