Owner`s manual

M SERIES DAC
TECHNICAL SUPPORT
____________________________________________________________________________
206
V78 CRM-1 DATA COMMAND SUMMARY
Command Description
CBr<cr> (r=Relay# 1 to 8, 0=all*)
Clear Buffer. Clears all buffered relay status
history (change of state).
DRr<cr> (r=Relay# 1 to 8, 0=all*) De-energize Relay(s)
ERr<cr> (r=Relay# 1 to 8, 0=all*) Energize Relay(s)
RAr<cr> (r=Relay# 1 to 8, 0=all*) Report All Buffered Relay Status History
RS r<cr> (r=Relay# 1 to 8, 0=all*)
Report Single Relay Status History Sample if
Available
SAr<cr> (r=Relay# 1 to 8, 0=all*) Sample. Read and report the current status of the
selected relay(s).
V78 CRM-1 I/O MODULE DYNAMIC CONFIGURATION
COMMAND SUMMARY
Command Description
RMn<cr> (n=1 to 3) Reporting Method. 1=Command, 2=Immediate, and 3=Schedule.
TTn<cr> (n=1 or 2) Time Tag. 1=Enable and 2=Disable.