Owner`s manual
M SERIES DAC
TECHNICAL SUPPORT
____________________________________________________________________________
205
V77 ADM-1 DATA COMMAND SUMMARY
Command Description
CAn<cr> (n=0 or 1 to 3)
Calibrate. 0=all, 1=25%, 2=50%, and 3=75% of Full
Scale (FS). Initiates auto-calibration. ADM-1 tests for
offsets and makes necessary corrections. Corrections
are continually applied to all reported data messages
until another Calibrate command is issued.
CBc<cr> (c=Ch# 1 to 16, 0=all)
Clear Buffer. Clears all old data from the buffer when
a new data set is started.
RAc<cr> (c=Ch# 1 to 16, 0=all) Report All Buffered Samples.
RS c<cr> (c=Ch# 1 to 16, 0=all) Report Single Sample if Available
SAc<cr> (c=Ch# 1 to 16, 0=all) Sample. Read and report sample at programmed setup.
V77 ADM-1 DYNAMIC CONFIGURATION COMMAND
SUMMARY
Command Description
AVn<cr> (n=1 to 4,000) Number of Samples to Average
DFn<cr> (n=1 or 2) Data Format. 1=Hexadecimal and 2=Decimal.
RMn<cr> (n=1 to 3) Reporting Method. 1=Command, 2=Immediate, and
3=Schedule.
SDn<cr> (n=1 or 2) Single Ended/Differential. 1=single ended and 2=differential.
SMn<cr> (n=1 or 2) Sampling Method. 1=Command, 2=Immediate, and
3=Schedule.
SPn<cr> (n=1 or 2) Sample Period. 1=Continuous and 2=Time.
SRn<cr> (n=1 to 4000) Sample Rate (Samples/Sec)
TTn<cr> (n=1 or 2) Time Tag. 1=Enable and 2=Disable.
UB n<cr> (n=1 or 2) Unipolar/Bipolar. 1=unipolar and 2=bipolar.
VRn<cr> (n=1 to 5) Set Voltage Range. 1 = +10V (with JP1 installed), 2 = +5V (or
0 to +10V), 3 = +2.5V (or 0 to +5V), 4 = +1.25V (or 0 to
+2.5V) and 5 = +0.625V (or 0 to +1.25V)