Contact rating: 3A @120 VAC, 2A @220 VAC or 28
VDC
resistive load
Contact resistance: 100 milliohms initially
Life expectancy: Mechanical: 20 million operations (min)
Electrical: 100,000 (min) @ full load
Vibration: 10g @ 55-110Hz, 0.062",
Dual amplitude(DA) -55Hz
Shock: 10g
Voltage isolation: 500 Vrms Channel-Channel & Channel-Ground
Connector: DB-25 female
Power Requirements: +5VDC, 300ma typical when all relays
are on –
(provided by M16/M8 power supply).
Software Control: Relays individually programmable to act upon,
record and/or report events by time, or
on demand.
Environmental: Operating temperature range 0
o
to 55
o
C
Storage temperature range -55
o
to 85
o
C
Humidity 5% to 95% non-condensing
V79 PDI-1 SWITCH INPUT STATUS MODULE
NOTE: These values are typical for 25
o
C unless otherwise noted)
Inputs: 16 with individual ground returns or
common
(single-point) ground.
Drive Distance: Up to 1000 Ohms cable resistance, for
example: AWG 36 - 2400 ft., AWG 24 -
15000 ft.,
AWG 22 - 62000 ft.