Owner`s manual

M SERIES DAC
CABLING
____________________________________________________________________________
8
V71 CABLING
The V71 has a DB-25 and two RJ-45 connectors for interface to the host terminal.
The V71 supports three line interfaces: EIA-232, EIA-422, and current loop. The
factory default setting provides EIA-232 line interface on the DB-25 port and the
EIA-232 RJ-45 port. The line interface is programmed by entering the V71
configuration mode (see page 47).
If you change the line interface to EIA-422 in configuration mode, the default
hardware settings provide EIA-422 line interface on the EIA-422/485 RJ-45 port.
You can change a hardware jumper setting on the module that provides EIA-422 line
interface on the DB-25 port. This procedure is discussed on page ???
Current loop line interface is provided on the DB-25 port only.
IMPORTANT: Before you proceed with cabling your equipment to the
V71, you should determine the required line interface for your application
and verify the connector type and pin/signal definitions for your equipment.
V71 DB-25 CABLING FOR EIA-232
The DB-25 port on the V71 has a male DTE type connector and uses the following
pins and signals for communication:
DB-25 PIN/SIGNAL DEFINITION FOR EIA-232 LINE INFORMATION
Pin
#
EIA-
232
Signal
Direction Description
1 PGND ---- Protective Ground
2 TX Output Transmit Data (data out)
3 RX Input Receive Data (data in)
4 RTS Output + 12 volts when the M16/M8 DAC is powered up.
5 CTS Input Handshake In, enable/disable the transmission of
characters
7 SGND ---- Signal Ground
20 DTR Output Handshake Out, enable/disable the receiving of
characters