Owner`s manual

M SERIES DAC
BASE UNIT AND MODULE OPERATION
____________________________________________________________________________
130
V72 CONFIGURATION DIAGNOSTIC LED DESCRIPTION
Flashing
LED
Description
1 Non-volatile Memory Fault. The data stored in the non-volatile RAM
for the V72's location contained an error. This causes the device in
question to be programmed with default parameter information and the
IP and Gateway addresses and the subnet mask will be set to 0.0.0.0.
The module will need to be reconfigured and reset before it can operate.
This symptom will occur when the V72 is installed into a module slot
previously occupied by a different module type.
2 Ethernet Address Fault. If an error occurs in the retrieval of the
module's Ethernet address, the address will be set to all 0s, an invalid
address. Before the module can operate, it will need to be programmed
with a proper address. This address cannot be programmed directly by
the user. Contact BayTech if this LED symptom occurs.
3 IP Address Fault. When a module is first installed, it will program its IP
Address to 0.0.0.0. The IP Address will need to be programmed before
the module can operate.
4 Subnet Mask Fault. When a module is first installed, it will program its
Subnet Mask to 0.0.0.0. The Subnet Mask will need to be programmed
before the module can operate.
NOTE: When you power up the M-Series DAC with a V72 installed for the
first time, the LEDs for Ports 3 and 4 for the V72 will flash continuously until
you program the IP Address and Subnet Mask (see Section 5) and reset the
unit.
OPERATIONAL MODE
When the module passes it’s hardware and configuration checks, it will then enter
operational mode. In operational mode, the following LED indications may be
observed.