Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE OPERATION
____________________________________________________________________________
125
Device C (2,3) 3
Device D (2,4) 4
Device A (3,1) 5
Device B (3,20) 6
Device C (3,3) 7
Device D (3,4) 8
Immediate Data Collection I
Configure C
Manual Connection M
Unit Reset R
Module Status S
Logout T
<Your ‘TELNET’ connection has been terminated>
ASCII STRING COMMAND METHOD
Serial I/O module ports(V74/V75) can also be selected by sending an ASCII character
string to the V72 host module that consists of the Port Select Code (default is $BT), the
desired Serial I/O module number (2 to 3 for M3 DAC), (2 to 6 for M6 DAC), (2 to 9 for
M9 DAC), and (2 to 16 for the M16 DAC), the desired Serial I/O module port number (1
to 4), and <cr>.
For example, to select Port 1 of a V74 module installed as Module 2 using the default
Port Select Code, send $BT2,1<cr>.
To disconnect, either select another V72 module or send the disconnect sequence. The
disconnect sequence consists of the Port Select Code followed by <cr> (e.g., $BT<cr>).
Once you disconnect, you can logout by typing LOGOUT<cr>.
NOTE: These commands are illustrated using the default port select code
($BT).