Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE OPERATION
____________________________________________________________________________
119
Set Unit Number 3
Program Password 4
Exit System Menu X
Enter Request:
For detailed Control Board System Menu information see the M-Series DAC Owner’s
Manual Number U140E111-02.
MANUAL CONNECTION
The “Manual Connection” selection for the V72 menu is used to make a module level
connection which is used for sending commands to the module. The “Manual
Connection” is used to make a connection to a module such as the Control Relay
Module, A-to-D Module, Event Counter Module, main board, etc. Use the “Manual
Connection” for module connections other than a Serial I/O module unless you want
to operate a Serial I/O module in the Command Mode of operation. The “Manual
Connection” selection should not be used for configuration.
By responding to the Enter Request: message at the end of the V72 menu with “M” you
receive a response similar to the following:
Device A (2,1 1
Device B (2,2 2
Device C (2,3 3
Device D (2,4 4
Device A (3,1 5
Device B (3,2 6
Device C (3,3 7
Device D (3,4 8
Immediate Data Collection I
Configure C
Manual Connection M
Unit Reset R
Module Status S
Logout T
Enter Request: M
Enter Module number: 2
Enter Port number (<CR> for none): 3