Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE OPERATION
____________________________________________________________________________
116
To login, enter password. (default is BTA in capital letters)
Login:
Login successful.
Attention Character: ;
Device A (2,1 1
Device B (2,2 CX. 2
Device C (2,3 3
Device D (2,4 4
Device A (3,1 5
Device B (3,2 6
Device C (3,3 7
Device D (3,4 8
Immediate Data Collection I
Configure C
Manual Connection M
Unit Reset R
Module Status S
Logout T
Enter Request :
The names in the left column are the same as programmed for the Serial I/O Port Device
Names and the (m,n) numbers in the middle correspond to the module and port. Type
the number corresponding to the desired V72 module to select that port followed by
<ENTER>. Type "C" to receive the "Configuration" selection menu , "X" to exit, or "T"
to logout.
Once a port is selected, you can select another port by sending the Attention character
five times followed by a one second delay to invoke the port selection menu. If you type
"T" to logout, the V72 will respond with the following:
< Your ‘TELNET’ connection has terminated>
NOTE: The “CX” in the above menu selection indicates that Device B
(Module 2, Port 2) has been selected by another session hosted by the V72.
Users will see the following message when the V72 Ethernet host module wants to
connect with a previously established port connection made by another host module on
the M-Series DAC unit.