Owner`s manual
M SERIES DAC
BASE UNIT AND MODULE CONFIGURATION
____________________________________________________________________________
100
Send "B" for 115.2K baud rate. The V93A will respond with the reconfigured status of
the port as follows:
Module 1 Serial Port Configuration :
Xon / XoffPort Device Name Baud
Rate
Word
Size
Stop
Bits
Parity
Xmit Recv
1 Device A 115.2K 8 1 None Off Off
Exit/Save 1 Set Stop Bits 4
Set Baud Rate 2 Set Parity 5
Set Word Size 3 Set Xon/Xoff 6
Enter Request :
You can now select other options from the menu.
If there are no other changes, send "1" (Exit/Save) and the V93A will respond with:
Save Changes Permanently ? (Y/N) :
If you type "Y", the new configuration for the selected port is stored permanently in non-
volatile memory until. If you type āNā the V93A will return to the main configuration
menu.
NOTE: If you are configuring the V93A from the EIA-232 port, the V93A
will respond with:
Change Device to NEW Configuration
Before Answering This Request.
IMPORTANT: This message reminds you to change the serial port
configuration of the host device now. If they do not match, the V93A will be
unable to interpret the next command. If this happens, cycle power on the M-
Series DAC and reconfigure the unit.
PORT DEVICE NAME
Type ā3ā (in the configuration main menu) and <cr> to change the port device name.
The module will respond:
Module 1 Serial Port Configuration :
Xon / XoffPort Device Name Baud
Rate
Word
Size
Stop
Bits
Parity
Xmit Recv
1 Device D 9600 8 1 None Off Off