Owner`s manual

35
5.2.1.3 LOCAL OPERATION
The RPC’s main menu allows you to monitor and control equipment
attached to each of the RPC-2 RDR and RPC-2 MD01’s six receptacles.
From this menu, you can turn on, turn off, or reboot attached equipment,
individually, or all equipment, simultaneously.
The RPC recognizes three basic operating commands: ON n<cr>, OFF
n<cr>, and REBOOT n<cr>, where n represents the outlet number and
<cr> represents a carriage return.
There are six red LEDs on the front of the RPC unit. There is a
corresponding red LED for each of the RPC’s six receptacles. If any or all
of the LEDs are illuminated, corresponding receptacle(s) are turned "ON,"
and consequently, attached equipment is receiving power. If any or all of
the LED’s are not illuminated, corresponding receptacle(s) are turned
“OFF.”
Accessing Main Menu Power on the RPC unit. The following outlet
and circuit breaker status menu appears:
RPC-2 Series
(c) 1997 by BayTech
F2.07
Circuit Breaker : On
1) . . . OUTLET 1 : Off
2) . . . OUTLET 2 : Off
3) . . . OUTLET 3 : Off
4) . . . OUTLET 4 : Off
5) . . . OUTLET 5 : Off
6) . . . OUTLET 6 : Off
RPC >
RPC OWNER’S MANUAL
____________________________________________________________