Owner`s manual
11
RPC-3 AND RPC-3A QUICK START
____________________________________________________________
2.3 A QUICK START FOR RPC-3, RPC-3A and
RPC-5
RPC-5 Note: The RPC-3 and RPC-5 are configured in a similar
manner. This quick start will reference the RPC-3 menus. The only
programming differences for the RPC-5 pertain to the number of
receptacles shown in the menus.
NOTE: Inlet #1 supplies power to the logic of the RPC-5, this inlet must
have power for the unit to operate.
LOCAL ACCESS
EIA-232 SERIAL Using the 9FRJ45PC-1 adapter and the
CONNECTION RJ08X007 (8-pin crossed) cable, connect the
serial port of your computer to the RJ-45
port labeled “EIA-232” on the RPC unit.
REMOTE ACCESS
NETWORK PORT Using a straight 10Base-T cable, connect
CONNECTION the port labeled Ethernet on the RPC to the
network hub. Establish a Telnet client
session and login from your workstation.
COMMUNICATIONS Load serial port communications software. Set
SOFTWARE serial communications parameters to 9600
bps, 8 data bits, 1 stop bit, and no parity.