Specifications
BayTech Addendum Publication No. Z140A186
Reference BayTech Manual Publication No. U140E121-03 Page 9 of 10
5.1 MAIN CONFIGURATION MENU
The DS73 will respond to the receiving of $CONFIG<cr> with an identification block and a menu of the available
configuration options similar to the following:
DS-Series DS73
Unit: 1 Module: 1
F 1.05, copyright (c) 1995
Bay Technical Associates
IP Address: 0.0.0.0
Subnet Mask: 0.0.0.0
Gateway Address: 0.0.0.0
Select Code: $BT
Ethernet Address: 00.C0.48.12.34.56
Client Msg/Login: enabled/enabled
Unit Memory (MB) 2
Active Connections: 2
IP Address............... 1
Subnet Mask.............. 2
Gateway.................. 3
Select Code.............. 4
Password................. 5
User Interface............6
Exit..................... X
>
NOTE: The line showing the amount of memory between the "Client Msg/Login" line and the "Active Connections"
line is displayed only if an M03 memory module is installed.
You can now make whatever changes are necessary by responding to the above menu. The "X" selection (Exit
Configuration) will return you to the operations mode.
5.2 IP ADDRESS
By responding to the Enter selection: message at the end of the main configuration menu with "1" (IP Address), you
can program the IP address. The DS73 will respond with:
Enter IP address in dotted decimal form:
Enter the desired IP address as a series of four numbers separated by periods (e.g., 197.3.14.9) followed by Carriage
Return.
NOTE: The first part of the IP address is determined by assigned network address.
IMPORTANT: The IP address must be programmed before the DS73 module can be accessed on the network. After
programming the IP address, the DS-Series unit must be reset for the new information to take effect.
5.3 SUBNET MASK
By responding to the Enter selection: message at the end of the main configuration menu with "2" (Subnet Mask),
you can program the Subnet Mask. The DS73 will respond with:
Enter Subnet Mask in dotted decimal form:
Enter the desired Subnet Mask as a series of four numbers separated by periods (e.g., 255.255.255.0) followed by
Carriage Return.
IMPORTANT: The Subnet Mask must be programmed before the DS73 module can be accessed on the network.
After programming the Subnet Mask, the DS-Series unit must be reset for the new information to take effect.
5.4 GATEWAY
By responding to the Enter selection: message at the end of the main configuration menu with "3" (Gateway), you
can program the Gateway or router address. The DS73 will respond with:
Enter Gateway address in dotted decimal form:
Enter the desired Gateway or router address as a series of four numbers separated by periods (e.g., 197.3.14.1)
followed by Carriage Return.
IMPORTANT: After programming the Gateway address, the DS-Series unit must be reset for the new information to
take effect.