Specifications

BayTech Addendum Publication No. Z140A186
Reference BayTech Manual Publication No. U140E121-03 Page 10 of 10
5.5 SELECT CODE
By responding to the Enter selection: message at the end of the main configuration menu with "4" (Select Code), you
can change the port select code to any ASCII character string from 1 to 8 characters. The DS73 will respond with:
Enter Select Code (8 chars max):
Type the desired port select code followed by <ENTER>. The DS73 saves the new port select code permanently in
the non-volatile memory and return to the main configuration menu.
NOTE: The select code is case sensitive. You cannot program the port select code to be $BT from the service port
or service modem.
NOTE: It is not necessary to reset the unit for this option to take effect.
5.6 PASSWORD
By responding to the Enter selection: message at the end of the main configuration menu with "5" (Password), you
can program the DS73 Password. The password is used for security purposes to prevent unauthorized users from
connecting to the DS73 and accessing its functions. The DS73 will respond with a menu similar to the following:
Current password: BTA
Enter Password (8 chars max):
Type the desired password up to eight ASCII characters. Press <ENTER> to return to the main configuration menu.
NOTE: The password is case sensitive. Any non-alphanumeric character including <BACKSPACE> and <DELETE>
or a password greater than eight characters is interpreted as an input error and you will be prompted to enter the
password again.
Terminate the password entry by typing the <ENTER> key. The DS73 will respond with:
Accept password as typed above? (Y/N) :
Press "Y" to accept the new password or "N" to reject it. If you press "N", the DS73 will return to the "Enter
Password" prompt. If you type "Y", the DS73 will return to the main configuration menu.
NOTE: It is not necessary to reset the unit for this option to take effect.
5.7 USER INTERFACE
By responding to the Enter selection: message at the end of the main configuration menu with "6" (User Interface),
you can configure the DS73 to either display or not display the welcome message that is sent to the workstation
when a connection is made to the DS73. You can also enable or the disable the login procedure that follows the
welcome message. The DS73 will respond with:
Enable/Disable Welcome Message? (E/D):
Press "E" to enable the welcome message, "D" to disable the welcome message, or <ENTER> to skip this option. The
DS73 will respond with:
Enable/Disable Login? (E/D):
Press "E" to enable the login procedure, "D" to disable the login procedure, or <ENTER> to skip this option. The
DS73 will return to the main configuration.
NOTE: It is not necessary to reset the unit for this option to take effect.